Notes

What -62 °C to 235 °C Means in Practice

A temperature range on a datasheet is a claim about the material, not a promise about your part. The gap between the two is where most failures come from. Here is how the numbers are produced.

Where the Numbers Come From

The range is established by ageing tests. Samples are held at a series of temperatures for a defined period, then measured for hardness change, tensile strength and elongation. The limits are the points where those properties stay within an agreed percentage of the original values.

That is a laboratory definition. It says the material still behaves like silicone at those temperatures. It does not say your part still seals at those temperatures under load, because compression, media and cycle count all change the answer.

The Cold End: -62 °C

At low temperature silicone does not become brittle the way ordinary rubber does, but it does stiffen. A 50 Shore A compound at -60 °C behaves more like 80 Shore A at room temperature: harder, less conformable, slower to recover.

For a static seal in a groove, that is usually acceptable. For a case that has to be peeled off a device, or a pad that has to conform to a surface, the part may simply not do its job at the cold limit even though the material is within specification. Say so on the drawing if cold flexibility matters, and the compound can be adjusted.

The Hot End: 235 °C

At the hot end the mechanism is different. Silicone does not melt; it gradually cross-link changes, and the material hardens and loses elongation. Continuous operation at 235 °C is possible, but the service life is finite and shorter than at 150 °C.

Intermittent excursions to around 300 °C are survivable for short periods because the thermal mass of the part delays the internal temperature rise. That is not the same as running at 300 °C.

Why Continuous and Intermittent Limits Differ

Continuous rating assumes the part spends its life at that temperature. Intermittent rating assumes short exposures followed by long recovery. The difference is not marketing caution: at continuous high temperature the material keeps ageing, and at intermittent temperature it partly recovers between cycles.

For a heating element, the element surface temperature is the number that matters, not the ambient. A heater rated at 235 °C surface can sit inside equipment whose ambient is 60 °C, and the material sees the surface figure.

What to Put on the Drawing

State the service conditions rather than a single number:

  • Ambient temperature range the part will see.
  • Surface temperature if the part touches a heat source.
  • Whether the exposure is continuous or cyclic, and the cycle length.
  • Any contact with oil, coolant or cleaning agents.

With those four lines on the drawing, the grade can be selected against the real duty rather than a datasheet headline, and the sample is far more likely to pass on the first attempt.